PETROLEUM PRODUCTS COMPOSITE
AUTOSAMPLER
 

ANALYSER ANCILLARY
BLENDING RUNDOWN AUTOSAMPLER:
Blended fuels autosampling according to ISO 3171;
ASTM D4177 and IP Petroleum.

This is a blending management tool to track performances of
finished products for on-line analyser's certification;
blending recipes optimization or NIR model development :

purpose is to collect a representative sample throughout the
blend for laboratory analysis.
The portative fuels autosampler ISOSAMPLE 1500 grabs
automatically from blender outlet successive samples in
proportion to flow or time to be stored in a transportation
piston floating cylinder receiver for subsampling in lab
analysers.
CRUDE-OIL to REFINED PRODUCTS AUTOSAMPLER:
According to the requirements of the most usual
standards :ISO 3171 ; ANSI/ASTM D4177 ; IP
Petroleum.

Main benefit of ISOSAMPLE 5000 is to integrate the
complete line of features required to keep sample
integrity :
- Large bore By-pass Loop Isokinetic
-Sample extracted from Process Line directly stored in
piston floating cylinder Receiver Chamber to suit with
splitted phase crude-oil.
- Integrated mixer to prevent stratification of heavier
fractions during the sample transfer to the 1 liter
portable receiver
- Control Unit monitoring the amount of sample
contained inside of Sample Receiver and featuring a
sampling software in compliance with Service Factor
Requirements (ISO 3171 )
.
The Right Measure of Your Success